Chhatrapati Sambhajinagar
08048032498

fully automatic controllers

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KDM SD WLC DW Three Phase Star Delta Pump Starter Controller with Water Level Controller for Dewatering Application SEGMENT MODELS Fully Automatic STARTER • Contactor based starter, MCB Included DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side / Motor Side) • Reverse Phase, Voltage & Current Unbalance • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current • Moisture Sensor Connection for Leak Detection – Automatically trips the pump upon moisture detection • Thermal Sensor Connection - Provides winding temperature protection by tripping the pump in case of overheating TIMER • Power ON Timer • Star Delta Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS (FEATURES) • Fully automatic Water Level Controller • Facility to connect Float Switch / Level Sensors / Magnetic Switch etc LED INDICATIONS • Power / Pump ON • SPP / CUB / RP • OC / Overload • UC / Dryrun • Tank Empty • Moisture Sensor • Current • Thermal Sensor SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Float Auto / Bypass • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 130 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V APPLICATIONS • Treated water sump drainage • Industrial wastewater handling • Dewatering from sumps • Flood water handling / emergency drainage • Sludge dewatering in STP / ETP SUITABLE FOR PUMPSET • Self-Priming Dewatering Pumps • Centrifugal Dewatering Pumps • High Head Dewatering Pumps • Construction Site Dewatering Pumps • Storm Water / Flood Dewatering Pumps

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KDM DOL WLC DW Three Phase DOL Pump Starter Controller with Water Level Controller for Dewatering Application SEGMENT MODELS Fully Automatic STARTER • Contactor based starter, MCB Included DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side / Motor Side) • Reverse Phase, Voltage & Current Unbalance • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current • Moisture Sensor Connection for Leak Detection - Automatically trips the pump upon moisture detection • Thermal Sensor Connection - Provides winding temperature protection by tripping the pump in case of overheating TIMER • Power ON Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS (FEATURES) • Fully automatic Water Level Controller • Facility to connect Float Switch / Level Sensors / Magnetic Switch etc LED INDICATIONS • Power / Pump ON • SPP / CUB / RP • OC / Overload • UC / Dryrun • Tank Empty • Moisture Sensor • Current • Thermal Sensor SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Float Auto / Bypass • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 30 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V APPLICATIONS • Dewatering from sumps • Flood water handling / emergency drainage • Sludge dewatering in STP / ETP • Industrial wastewater handling • Treated water sump drainage SUITABLE FOR PUMPSET • Submersible Dewatering Pumps • Sewage Submersible Pumps • Mud Pumps • Openwell Submersible Pumps • Vertical Dewatering Pumps

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KDM SD WLC PS Three Phase Star Delta Pump Starter Controller with Water Level Controller for Pressure Switch Applications SEGMENT MODELS Fully Automatic STARTER • Contactor based starter, MCB Included DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side / Motor Side) • Reverse Phase, Voltage & Current Unbalance • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current TIMER • Power ON Timer • Star Delta Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) • Cyclic ON - OFF Timer (Site Settable: Off - 5 - 720 min) • Toggle Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS (FEATURES) • Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS • Power / Pump ON • SPP / CUB / RP • OC / Overload • UC / Dryrun • LT Empty • PS / UTF • Current • Timer SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Float Auto / Bypass • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 130 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V APPLICATIONS • Booster pumps in high-rise buildings • Hydro-pneumatic water supply systems • Industrial pressure boosting pumps • Fire line main pump systems • Process water pressure systems in industries SUITABLE FOR PUMPSET • Submersible / Openwell Star Delta Pumpsets • End Suction Centrifugal Star Delta Pumpsets • Vertical Multistage Star–Delta Pumpsets • Horizontal Split Case Star–Delta Pumpsets • Fire Fighting Main Pump Star Delta Pumpsets

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KDM DOL WLC PS Three Phase DOL Pump Starter Controller with Water Level Controller for Pressure Switch Applications SEGMENT MODELS Fully Automatic STARTER • Contactor based starter, MCB Included DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side / Motor Side) • Reverse Phase, Voltage & Current Unbalance • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current TIMER • Power ON Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) • Cyclic ON - OFF Timer (Site Settable: Off - 5 - 720 min) • Toggle Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS (FEATURES) • Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS • Power / Pump ON • SPP / CUB / RP • OC / Overload • UC / Dryrun • LT Empty • PS / UTF • Current • Timer SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Float Auto / Bypass • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 30 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V APPLICATIONS • Water transfer booster systems • AHUs in HVAC Systems • Industrial water pressure control • Fire line jockey pump systems SUITABLE FOR PUMPSET • Centrifugal Monoblock Pumpsets End Suction Pumpsets Multistage Booster Pumpsets Air Handling Units (AHUs)

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KTP 99 WLC PS Three Phase DOL Pump Starter Controller with Water Level Controller for Pressure Switch Applications SEGMENT MODELS Fully Automatic STARTER • Electronic starter (Relay Based 40 Amp.) DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side / Motor Side) • Reverse Phase, Voltage & Current Unbalance • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current TIMER • Power ON Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) • Cyclic ON - OFF Timer (Site Settable: Off - 5 - 720 min) • Toggle Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS (FEATURES) • Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS • Power / Pump ON • SPP / CUB / RP • OC / Overload • UC / Dryrun • LT Empty • PS / UTF • Current • Timer SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Float Auto / Bypass • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 7.5 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V • Max. Current: 16A APPLICATIONS • Constant pressure water supply systems • Booster pump systems in buildings • Industrial water pressure control • Tap Feeding Commercial Projects SUITABLE FOR PUMPSET • Vertical & Horizontal Multistage Pumpset • Vertical & Horizontal Inline Pumpset • Centrifugal Monoblock Pumpset • Submersible Booster Pumpset

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

THREE PHASE WLC Three Phase Water Level Controller (Attachment Series) SEGMENT MODELS Fully Automatic STARTER • Compatible with All Standard DOL and Star-Delta Motor Starters TIMER • Power ON Timer TECHNOLOGY • Microcontroller Software Technology Embedded Controller OTHERS (FEATURES) • Two tank fully automatic Water Level Controller • Facility to connect Float Switch / Level Sensors / Magnetic Switch etc LED INDICATIONS • Upper Tank Full • Upper Tank Empty • Pump ON • Lower Tank Full • Lower Tank Empty SWITCHES • WLC Auto / Unit OFF / WLC Bypass APPLICATIONS • Domestic water supply • Lawn sprinklers • Water supply to over head tanks • Small farm Irrigation • Dewatering from sumps SUITABLE FOR PUMPSET • All types of DOL Pumpset • All types of Star Delta Pumpset

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KDM SD WLC Three Phase Star Delta Pump Starter Controller with Water Level Controller SEGMENT MODELS Fully Automatic STARTER • Contactor based starter, MCB Included DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side / Motor Side) • Reverse Phase, Voltage & Current Unbalance • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current TIMER • Power ON Timer • Star Delta Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) • Cyclic ON - OFF Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS (FEATURES) • Two tank fully automatic Water Level Controller • Facility to connect Float Switch / Level Sensors / Magnetic Switch etc LED INDICATIONS • Power / Pump ON • SPP / CUB / RP • OC / Overload • UC / Dryrun • LT Empty • UT Full • Current • Timer SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Float Auto / Bypass • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 130 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V APPLICATIONS • Large overhead tank filling • Industrial water supply • Community water supply • Agricultural irrigation • Dewatering from sumps SUITABLE FOR PUMPSET • Borewell / Openwell Submersible Star Delta Pumpsets • Centrifugal Monoblock Star Delta Pumpsets • Agricultural Irrigation Star Delta Pumpsets • Industrial Water Supply Star Delta Pumpsets

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KDM DOL WLC Three Phase DOL Pump Starter Controller with Water Level Controller SEGMENT MODELS Fully Automatic STARTER • Contactor based starter, MCB Included DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side / Motor Side) • Reverse Phase, Voltage & Current Unbalance • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current TIMER • Power ON Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) • Cyclic ON - OFF Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS (FEATURES) • Two tank fully automatic Water Level Controller • Facility to connect Float Switch / Level Sensors / Magnetic Switch etc LED INDICATIONS • Power / Pump ON • SPP / CUB / RP • OC / Overload • UC / Dryrun • LT Empty • UT Full • Current • Timer SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Float Auto / Bypass • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 30 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V APPLICATIONS • Ground water supply to water works • Water supply to single / mulple overhead tanks • Domestic and community water supply • Gardening and small farm irrigation • Dewatering from sumps SUITABLE FOR PUMPSET • All types of DOL Pumpset • Borewell & Openwell Subersible DOL Pumpset • Centrifugal Monoblock DOL Pumpset • Dewatering DOL Pumpset • Induction Motors

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KPM 33 TTC Three Phase DOL Pump Starter Controller with Water Level Controller SEGMENT MODELS Fully Automatic STARTER • Electronic starter (Relay Based 40 Amp. / Phase) DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side) • Reverse Phase, Voltage & Current Unbalance • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current TIMER • Power ON Timer TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings • Password Protection for Settings OTHERS (FEATURES) • Two tank fully automatic Water Level Controller • Facility to connect Float Switch / Level Sensors / Magnetic Switch etc SWITCHES • Value Setting (4 Switches) • ON / OFF • Over Current • Under Current • Auto • Manual TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 7.5 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V • Max. Current: 16A APPLICATIONS • Ground water supply to water works • Water supply to single / mulple overhead tanks • Domestic and community water supply • Water transfer between tanks SUITABLE FOR PUMPSET • Borewell Subersible Pumpset • Openwell Submersible Pumpset • All types of DOL Pumpset

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KPM 33 BORE Three Phase DOL Pump Starter Controller with Water Level Controller SEGMENT MODELS Fully Automatic STARTER • Electronic starter (Relay Based 40 Amp. / Phase) DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side) • Reverse Phase, Voltage & Current Unbalance Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current TIMER • Cyclic ON - OFF Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings • Password Protection for Settings OTHERS (FEATURES) • Borewell Automation Controller • Facility to connect Float Switch / Level Sensors for Upper Tank SWITCHES • Value Setting (4 Switches) • ON / OFF • Over Current • Under Current • OFF Time • ON Time TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 7.5 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V • Max. Current: 16A APPLICATIONS • Construction Site Water Supply • Water Supply for Schools, Hospitals & Institutions • Domestic Water Supply for Houses & Apartments • Gardening and small farm irrigation • Agricultural Irrigation in Farms & Fields SUITABLE FOR PUMPSET • Borewell Subersible Pumpset • Openwell Submersible Pumpset • All types of DOL Pumpset

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KTP 99 WLC Three Phase DOL Pump Starter Controller with Water Level Controller SEGMENT MODELS Fully Automatic STARTER • Electronic starter (Relay Based 40 Amp. / Phase) DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side / Motor Side) • Reverse Phase, Voltage & Current Unbalance Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current TIMER • Power ON Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) • Cyclic ON - OFF Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS (FEATURES) • Two tank fully automatic Water Level Controller • Facility to connect Float Switch / Level Sensors / Magnetic Switch etc LED INDICATIONS • Power / Pump ON • SPP / CUB / RP • OC / Overload • UC / Dryrun • LT Empty • UT Full • Current • Timer SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Float Auto / Bypass • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 7.5 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V • Max. Current: 16A APPLICATIONS • Construction site • Domestic and community water supply • Water supplies for high rise building • Flood water handling • Small farm Irrigation • Industrial Machines, Fans & Blowers • Dewatering from sumps SUITABLE FOR PUMPSET • All types of DOL Pumpset • Borewell & Openwell Subersible DOL Pumpset • Centrifugal Monoblock DOL Pumpset • Dewatering DOL Pumpset • Induction Motors

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KTP 66 WLC Three Phase DOL Pump Starter Controller with Water Level Controller SEGMENT MODELS Fully Automatic STARTER • Electronic starter (Relay Based 40 Amp. / Phase) DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side / Motor Side) • Reverse Phase, Voltage & Current Unbalance Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current TIMER • Power ON Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) • Cyclic ON - OFF Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS (FEATURES) • Two tank fully automatic Water Level Controller • Facility to connect Float Switch / Level Sensors / Magnetic Switch etc LED INDICATIONS • Power / Pump ON • SPP / CUB / RP • OC / Overload • UC / Dryrun • LT Empty • UT Full • Current • Timer SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Float Auto / Bypass • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 7.5 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V • Max. Current: 16A APPLICATIONS • Construction site • Domestic and community water supply • Water supplies for high rise building • Flood water handling • Small farm Irrigation • Industrial Machines, Fans & Blowers • Dewatering from sumps SUITABLE FOR PUMPSET • All types of DOL Pumpset • Borewell & Openwell Subersible DOL Pumpset • Centrifugal Monoblock DOL Pumpset • Dewatering DOL Pumpset • Induction Motors

Phone Number

08048032498

Please keep 0 before dialling the number.

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Address Chhatrapati Sambhajinagar, Maharashtra, India

Chhatrapati Sambhajinagar, India, 431001