Chhatrapati Sambhajinagar
08048032498
FULLY AUTOMATIC CONTROLLERS

KDM DOL WLC DW Three Phase DOL Pump Starter Controller with Water Level Controller for Dewatering Application

In stockcod not available
Phone Number

08048032498

Please keep 0 before dialling the number.

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Address Chhatrapati Sambhajinagar, Maharashtra, India

Chhatrapati Sambhajinagar, India, 431001

Description

KDM DOL WLC DW Three Phase DOL Pump Starter Controller with Water Level Controller for Dewatering Application SEGMENT MODELS Fully Automatic STARTER • Contactor based starter, MCB Included DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side / Motor Side) • Reverse Phase, Voltage & Current Unbalance • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current • Moisture Sensor Connection for Leak Detection - Automatically trips the pump upon moisture detection • Thermal Sensor Connection - Provides winding temperature protection by tripping the pump in case of overheating TIMER • Power ON Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS (FEATURES) • Fully automatic Water Level Controller • Facility to connect Float Switch / Level Sensors / Magnetic Switch etc LED INDICATIONS • Power / Pump ON • SPP / CUB / RP • OC / Overload • UC / Dryrun • Tank Empty • Moisture Sensor • Current • Thermal Sensor SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Float Auto / Bypass • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 30 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V APPLICATIONS • Dewatering from sumps • Flood water handling / emergency drainage • Sludge dewatering in STP / ETP • Industrial wastewater handling • Treated water sump drainage SUITABLE FOR PUMPSET • Submersible Dewatering Pumps • Sewage Submersible Pumps • Mud Pumps • Openwell Submersible Pumps • Vertical Dewatering Pumps

Keywords

Other Products

view all

6814772a5d263414004dd4a4 Card 2

product image
MULTI PUMP FIXED SPEED AUTOMATIC CONTROLLERS

KHP SD Three Phase Star Delta Multi Pump Fixed Speed Automation Controller SEGMENT MODELS Multi Pump STARTER • 1. Contactor based starter, MCB Included (Premium) DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side) • Reverse Phase, Voltage Unbalance • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) TIMER • Power ON Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) • Toggle Timer (Site Settable: Off - 5 - 720 min) • Cyclic ON - OFF / Force Changeover Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • All Parameters Fully Configurable at Site OTHERS (FEATURES) • Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS • Healty • SPP/VUB/RP • OC / Overload • UC / Dryrun • LT Empty • Pump 1 • UT Full • Pump 2 SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Pump 1 / Alternate / Pump 2 • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 60 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V APPLICATIONS • Booster pumps in high-rise buildings • Hydro-pneumatic water supply systems • Industrial pressure boosting pumps • Fire line main pump systems • Process water pressure systems in industries SUITABLE FOR PUMPSET • Submersible / Openwell Star Delta Pumpsets • End Suction Centrifugal Star Delta Pumpsets • Vertical Multistage Star–Delta Pumpsets • Horizontal Split Case Star–Delta Pumpsets • Fire Fighting Main Pump Star Delta Pumpsets

6814772a5d263414004dd4a4 Card 2

product image
MULTI PUMP FIXED SPEED AUTOMATIC CONTROLLERS

KHP DOL Three Phase DOL Multi Pump Fixed Speed Automation Controller SEGMENT MODELS Multi Pump STARTER • 1. Contactor based starter, MCB Included (Premium) • 2. Contactor based starter, MCB Included (Classic) • 3. Electronic starter (Relay Based 40 Amp.) Lite DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side) • Reverse Phase, Voltage Unbalance • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) TIMER • Power ON Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) • Toggle Timer (Site Settable: Off - 5 - 720 min) • Cyclic ON - OFF / Force Changeover Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • All Parameters Fully Configurable at Site OTHERS (FEATURES) • Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS • Healty • SPP/VUB/RP • OC / Overload • UC / Dryrun • LT Empty • Pump 1 • UT Full • Pump 2 SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Pump 1 / Alternate / Pump 2 • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 5.0 HP / 7.5 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V • Max. Current: 16A APPLICATIONS • Water transfer booster systems • AHUs in HVAC Systems • Industrial water pressure control • Fire line jockey pump systems SUITABLE FOR PUMPSET • Centrifugal Monoblock Pumpsets End Suction Pumpsets Multistage Booster Pumpsets Air Handling Units (AHUs)

6814772a5d263414004dd4a4 Card 2

product image
MULTI PUMP FIXED SPEED AUTOMATIC CONTROLLERS

MPA 22 Single Phase Monoblock Bosster Multi Pump Fixed Speed Automation Controller SEGMENT MODELS Multi Pump STARTER • Electronic starter (Relay Based 40 Amp.) DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Overload / Over Current (Site Settable) Dryrun / Under Current (Site Settable) TIMER • Power ON Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) • Toggle Timer (Site Settable: Off - 5 - 720 min) • Cyclic ON - OFF / Force Changeover Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • All Parameters Fully Configurable at Site OTHERS (FEATURES) • Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS • Healthy • OC / Overload • UC / Dryrun • Timer • LT Empty • Pump 1 • UT Full • Pump 2 SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Pump 1 / All ON / Pump 2 • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 3.0 HP • Phase: Single • Rated Voltage: 220V • Frequency: 50Hz • Voltage Range: 160 - 280V • Max. Current: 20A APPLICATIONS • Tap Feeding / Domestic Water Pressure Boosting • Overhead Tank Water Distribution • Bathroom & Shower Pressure Boosting • Garden Irrigation & Lawn Sprinklers • Car Washing Systems SUITABLE FOR PUMPSET • Mini Self-Priming Pump • Domestic Booster Pump • Inline Pressure Booster Pump