New Delhi
08048034795

multi pump fixed speed automatic controllers

6814772a5d263414004dd4a4 Card 2

product image
MULTI PUMP FIXED SPEED AUTOMATIC CONTROLLERS

KHP SD Three Phase Star Delta Multi Pump Fixed Speed Automation Controller SEGMENT MODELS Multi Pump STARTER β€’ 1. Contactor based starter, MCB Included (Premium) DISPLAY β€’ Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS β€’ Phase Failure (Supply Side) β€’ Reverse Phase, Voltage Unbalance β€’ Overload / Over Current (Site Settable) β€’ Dryrun / Under Current (Site Settable) TIMER β€’ Power ON Timer β€’ Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) β€’ Toggle Timer (Site Settable: Off - 5 - 720 min) β€’ Cyclic ON - OFF / Force Changeover Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY β€’ Microcontroller Software Technology Embedded Controller SETTINGS β€’ All Parameters Fully Configurable at Site OTHERS (FEATURES) β€’ Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS β€’ Healty β€’ SPP/VUB/RP β€’ OC / Overload β€’ UC / Dryrun β€’ LT Empty β€’ Pump 1 β€’ UT Full β€’ Pump 2 SWITCHES β€’ ON / Set PC β€’ OFF / Reset β€’ Auto / Manual β€’ Pump 1 / Alternate / Pump 2 β€’ Setting / Accept TECHNICAL SPECIFICATIONS β€’ Power Rating: 0.5 - 60 HP β€’ Phase: Three β€’ Rated Voltage: 440V β€’ Frequency: 50Hz β€’ Voltage Range: 280 - 480V APPLICATIONS β€’ Booster pumps in high-rise buildings β€’ Hydro-pneumatic water supply systems β€’ Industrial pressure boosting pumps β€’ Fire line main pump systems β€’ Process water pressure systems in industries SUITABLE FOR PUMPSET β€’ Submersible / Openwell Star Delta Pumpsets β€’ End Suction Centrifugal Star Delta Pumpsets β€’ Vertical Multistage Star–Delta Pumpsets β€’ Horizontal Split Case Star–Delta Pumpsets β€’ Fire Fighting Main Pump Star Delta Pumpsets

6814772a5d263414004dd4a4 Card 2

product image
MULTI PUMP FIXED SPEED AUTOMATIC CONTROLLERS

KHP DOL Three Phase DOL Multi Pump Fixed Speed Automation Controller SEGMENT MODELS Multi Pump STARTER β€’ 1. Contactor based starter, MCB Included (Premium) β€’ 2. Contactor based starter, MCB Included (Classic) β€’ 3. Electronic starter (Relay Based 40 Amp.) Lite DISPLAY β€’ Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS β€’ Phase Failure (Supply Side) β€’ Reverse Phase, Voltage Unbalance β€’ Overload / Over Current (Site Settable) β€’ Dryrun / Under Current (Site Settable) TIMER β€’ Power ON Timer β€’ Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) β€’ Toggle Timer (Site Settable: Off - 5 - 720 min) β€’ Cyclic ON - OFF / Force Changeover Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY β€’ Microcontroller Software Technology Embedded Controller SETTINGS β€’ All Parameters Fully Configurable at Site OTHERS (FEATURES) β€’ Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS β€’ Healty β€’ SPP/VUB/RP β€’ OC / Overload β€’ UC / Dryrun β€’ LT Empty β€’ Pump 1 β€’ UT Full β€’ Pump 2 SWITCHES β€’ ON / Set PC β€’ OFF / Reset β€’ Auto / Manual β€’ Pump 1 / Alternate / Pump 2 β€’ Setting / Accept TECHNICAL SPECIFICATIONS β€’ Power Rating: 0.5 - 5.0 HP / 7.5 HP β€’ Phase: Three β€’ Rated Voltage: 440V β€’ Frequency: 50Hz β€’ Voltage Range: 280 - 480V β€’ Max. Current: 16A APPLICATIONS β€’ Water transfer booster systems β€’ AHUs in HVAC Systems β€’ Industrial water pressure control β€’ Fire line jockey pump systems SUITABLE FOR PUMPSET β€’ Centrifugal Monoblock Pumpsets End Suction Pumpsets Multistage Booster Pumpsets Air Handling Units (AHUs)

6814772a5d263414004dd4a4 Card 2

product image
MULTI PUMP FIXED SPEED AUTOMATIC CONTROLLERS

MPA 22 Single Phase Monoblock Bosster Multi Pump Fixed Speed Automation Controller SEGMENT MODELS Multi Pump STARTER β€’ Electronic starter (Relay Based 40 Amp.) DISPLAY β€’ Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS β€’ Overload / Over Current (Site Settable) Dryrun / Under Current (Site Settable) TIMER β€’ Power ON Timer β€’ Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) β€’ Toggle Timer (Site Settable: Off - 5 - 720 min) β€’ Cyclic ON - OFF / Force Changeover Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY β€’ Microcontroller Software Technology Embedded Controller SETTINGS β€’ All Parameters Fully Configurable at Site OTHERS (FEATURES) β€’ Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS β€’ Healthy β€’ OC / Overload β€’ UC / Dryrun β€’ Timer β€’ LT Empty β€’ Pump 1 β€’ UT Full β€’ Pump 2 SWITCHES β€’ ON / Set PC β€’ OFF / Reset β€’ Auto / Manual β€’ Pump 1 / All ON / Pump 2 β€’ Setting / Accept TECHNICAL SPECIFICATIONS β€’ Power Rating: 0.5 - 3.0 HP β€’ Phase: Single β€’ Rated Voltage: 220V β€’ Frequency: 50Hz β€’ Voltage Range: 160 - 280V β€’ Max. Current: 20A APPLICATIONS β€’ Tap Feeding / Domestic Water Pressure Boosting β€’ Overhead Tank Water Distribution β€’ Bathroom & Shower Pressure Boosting β€’ Garden Irrigation & Lawn Sprinklers β€’ Car Washing Systems SUITABLE FOR PUMPSET β€’ Mini Self-Priming Pump β€’ Domestic Booster Pump β€’ Inline Pressure Booster Pump

6814772a5d263414004dd4a4 Card 2

product image
MULTI PUMP FIXED SPEED AUTOMATIC CONTROLLERS

KHP PNPN Single Phase Monoblock Multi Pump Fixed Speed Automation Controller SEGMENT MODELS Multi Pump STARTER β€’ 1. Contactor based starter, MCB Included (Premium) DISPLAY β€’ Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS β€’ Overload / Over Current (Site Settable) Dryrun / Under Current (Site Settable) TIMER β€’ Power ON Timer β€’ Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) β€’ Toggle Timer (Site Settable: Off - 5 - 720 min) β€’ Cyclic ON - OFF / Force Changeover Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY β€’ Microcontroller Software Technology Embedded Controller SETTINGS β€’ All Parameters Fully Configurable at Site OTHERS (FEATURES) β€’ Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS β€’ Healthy β€’ OC / Overload β€’ UC / Dryrun β€’ Timer β€’ LT Empty β€’ Pump 1 β€’ UT Full β€’ Pump 2 SWITCHES β€’ ON / Set PC β€’ OFF / Reset β€’ Auto / Manual β€’ Pump 1 / Alternate / Pump 2 β€’ Setting / Accept TECHNICAL SPECIFICATIONS β€’ Power Rating: 0.5 - 3.0 HP β€’ Phase: Single β€’ Rated Voltage: 220V β€’ Frequency: 50Hz β€’ Voltage Range: 160 - 280V β€’ Max. Current: 20A APPLICATIONS β€’ Tap Feeding / Domestic Water Pressure Boosting β€’ Overhead Tank Water Distribution β€’ Bathroom & Shower Pressure Boosting β€’ Garden Irrigation & Lawn Sprinklers β€’ Car Washing Systems SUITABLE FOR PUMPSET β€’ Mini Self-Priming Pump β€’ Domestic Booster Pump β€’ Inline Pressure Booster Pump

6814772a5d263414004dd4a4 Card 2

product image
MULTI PUMP FIXED SPEED AUTOMATIC CONTROLLERS

KHP OPN Single Phase Openwell Multi Pump Fixed Speed Automation Controller with Run Capacitors SEGMENT MODELS Multi Pump STARTER β€’ 1. Contactor based starter, MCB Included (Premium) β€’ 2. Electronic starter (Relay Based 40 Amp.) Lite DISPLAY β€’ Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS β€’ Overload / Over Current (Site Settable) Dryrun / Under Current (Site Settable) TIMER β€’ Power ON Timer β€’ Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) β€’ Toggle Timer (Site Settable: Off - 5 - 720 min) β€’ Cyclic ON - OFF / Force Changeover Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY β€’ Microcontroller Software Technology Embedded Controller SETTINGS β€’ All Parameters Fully Configurable at Site OTHERS (FEATURES) β€’ Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS β€’ Healthy β€’ OC / Overload β€’ UC / Dryrun β€’ Timer β€’ LT Empty β€’ Pump 1 β€’ UT Full β€’ Pump 2 SWITCHES β€’ ON / Set PC β€’ OFF / Reset β€’ Auto / Manual β€’ Pump 1 / Alternate / Pump 2 β€’ Setting / Accept TECHNICAL SPECIFICATIONS β€’ Power Rating: 0.5 - 2.0 HP β€’ Phase: Single β€’ Rated Voltage: 220V β€’ Frequency: 50Hz β€’ Voltage Range: 160 - 280V β€’ Max. Current: 20A APPLICATIONS β€’ Openwell Water Pumping Systems β€’ Overhead Tank Filling and Level Maintenance β€’ Water Transfer from Wells to Storage Tanks β€’ Water Supply Systems for Commercial Buildings SUITABLE FOR PUMPSET β€’ Openwell submersible pumpset β€’ Vertical openwell Pumpset β€’ Any pumpset with run capacitor requirements

6814772a5d263414004dd4a4 Card 2

product image
MULTI PUMP FIXED SPEED AUTOMATIC CONTROLLERS

KHP SUB Single Phase Submersible Multi Pump Fixed Speed Automation Controller with Start & Run Capacitors SEGMENT MODELS Multi Pump STARTER β€’ Electronic starter (Relay Based 40 Amp.) DISPLAY β€’ Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS β€’ Overload / Over Current (Site Settable) Dryrun / Under Current (Site Settable) TIMER β€’ Power ON Timer β€’ Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) β€’ Toggle Timer (Site Settable: Off - 5 - 720 min) β€’ Cyclic ON - OFF / Force Changeover Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY β€’ Microcontroller Software Technology Embedded Controller SETTINGS β€’ All Parameters Fully Configurable at Site OTHERS (FEATURES) β€’ Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS β€’ Healthy β€’ OC / Overload β€’ UC / Dryrun β€’ Timer β€’ LT Empty β€’ Pump 1 β€’ UT Full β€’ Pump 2 SWITCHES β€’ ON / Set PC β€’ OFF / Reset β€’ Auto / Manual β€’ Pump 1 / Alternate / Pump 2 β€’ Setting / Accept TECHNICAL SPECIFICATIONS β€’ Power Rating: 0.5 - 2.0 HP β€’ Phase: Single β€’ Rated Voltage: 220V β€’ Frequency: 50Hz β€’ Voltage Range: 160 - 280V β€’ Max. Current: 20A APPLICATIONS β€’ Borewell Water Pumping Systems β€’ Overhead Tank Filling and Level Maintenance β€’ Agricultural and Landscape Irrigation Systems β€’ Water Supply Systems for Residential and Commercial Buildings SUITABLE FOR PUMPSET β€’ Borewell subersible pumpset β€’ Openwell submersible pumpset β€’ Vertical openwell Pumpset β€’ Any pumpset with start & run capacitor requirements

Phone Number

08048034795

Please keep 0 before dialling the number.

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Address New Delhi, Delhi, India

New Delhi, India, 110001