SEGMENT MODELS Semi Automatic STARTER • Electronic starter (Relay Based 40 Amp.) DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current • Capacitor Cut Off Timer TIMER • OFF Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS (FEATURES) • Facility to connect Float Switch / Level Sensors for automatic pump cut-off when the tank is full LED INDICATIONS • Pump ON • Capacitor Cut Off Timer • OC / Overload • UC / Dryrun • High / Low Voltage • Voltage • Current • Off Timer SWITCHES • Pump ON • Pump OFF • Setting / Reset TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 2.0 HP / 3.0 HP / 5.0 HP • Phase: Single • Rated Voltage: 220V • Frequency: 50Hz • Voltage Range: 160 - 280V • Max. Current: 20A / 26A / 40A APPLICATIONS • Construction and infrastructure sites • Domestic and community water distribution • Farmhouse and rural water supply • Any application with borewell to overhead tank filling SUITABLE FOR PUMPSET • Borewell subersible pumpset • Openwell submersible pumpset • Vertical openwell Pumpset • Any pumpset with start & run capacitor requirements

Keywords

Other Products

view all

6814772a5d263414004dd4a4 Card 2

product image
MULTI PUMP FIXED SPEED AUTOMATIC CONTROLLERS

KHP SD Three Phase Star Delta Multi Pump Fixed Speed Automation Controller SEGMENT MODELS Multi Pump STARTER • 1. Contactor based starter, MCB Included (Premium) DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side) • Reverse Phase, Voltage Unbalance • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) TIMER • Power ON Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) • Toggle Timer (Site Settable: Off - 5 - 720 min) • Cyclic ON - OFF / Force Changeover Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • All Parameters Fully Configurable at Site OTHERS (FEATURES) • Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS • Healty • SPP/VUB/RP • OC / Overload • UC / Dryrun • LT Empty • Pump 1 • UT Full • Pump 2 SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Pump 1 / Alternate / Pump 2 • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 60 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V APPLICATIONS • Booster pumps in high-rise buildings • Hydro-pneumatic water supply systems • Industrial pressure boosting pumps • Fire line main pump systems • Process water pressure systems in industries SUITABLE FOR PUMPSET • Submersible / Openwell Star Delta Pumpsets • End Suction Centrifugal Star Delta Pumpsets • Vertical Multistage Star–Delta Pumpsets • Horizontal Split Case Star–Delta Pumpsets • Fire Fighting Main Pump Star Delta Pumpsets

6814772a5d263414004dd4a4 Card 2

product image
MULTI PUMP FIXED SPEED AUTOMATIC CONTROLLERS

KHP DOL Three Phase DOL Multi Pump Fixed Speed Automation Controller SEGMENT MODELS Multi Pump STARTER • 1. Contactor based starter, MCB Included (Premium) • 2. Contactor based starter, MCB Included (Classic) • 3. Electronic starter (Relay Based 40 Amp.) Lite DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side) • Reverse Phase, Voltage Unbalance • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) TIMER • Power ON Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) • Toggle Timer (Site Settable: Off - 5 - 720 min) • Cyclic ON - OFF / Force Changeover Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • All Parameters Fully Configurable at Site OTHERS (FEATURES) • Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS • Healty • SPP/VUB/RP • OC / Overload • UC / Dryrun • LT Empty • Pump 1 • UT Full • Pump 2 SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Pump 1 / Alternate / Pump 2 • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 5.0 HP / 7.5 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V • Max. Current: 16A APPLICATIONS • Water transfer booster systems • AHUs in HVAC Systems • Industrial water pressure control • Fire line jockey pump systems SUITABLE FOR PUMPSET • Centrifugal Monoblock Pumpsets End Suction Pumpsets Multistage Booster Pumpsets Air Handling Units (AHUs)

6814772a5d263414004dd4a4 Card 2

product image
MULTI PUMP FIXED SPEED AUTOMATIC CONTROLLERS

MPA 22 Single Phase Monoblock Bosster Multi Pump Fixed Speed Automation Controller SEGMENT MODELS Multi Pump STARTER • Electronic starter (Relay Based 40 Amp.) DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Overload / Over Current (Site Settable) Dryrun / Under Current (Site Settable) TIMER • Power ON Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) • Toggle Timer (Site Settable: Off - 5 - 720 min) • Cyclic ON - OFF / Force Changeover Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • All Parameters Fully Configurable at Site OTHERS (FEATURES) • Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS • Healthy • OC / Overload • UC / Dryrun • Timer • LT Empty • Pump 1 • UT Full • Pump 2 SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Pump 1 / All ON / Pump 2 • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 3.0 HP • Phase: Single • Rated Voltage: 220V • Frequency: 50Hz • Voltage Range: 160 - 280V • Max. Current: 20A APPLICATIONS • Tap Feeding / Domestic Water Pressure Boosting • Overhead Tank Water Distribution • Bathroom & Shower Pressure Boosting • Garden Irrigation & Lawn Sprinklers • Car Washing Systems SUITABLE FOR PUMPSET • Mini Self-Priming Pump • Domestic Booster Pump • Inline Pressure Booster Pump