Pune
08043694918

fully automatic controllers

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KTC 22 BOOSTER Single Phase Booster Pump Starter Controller with Water Level Controller for Pressure Switch Applications FEATURES STARTER • Electronic starter (Relay Based 40Amp) DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Overload / Over Current (Site Settable ) • Dryrun / Under Current(Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current TIMER • Power ON Timer • Toggle Timer (Site Settable : Off-1-999 min) TECHNOLOGY • Microcontroller software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS • Facility to connect Pressure Switch / Float •Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS • Power / Pump ON • OC / Overload • UC / Dryrun • PS / UTF • LT Empty • Voltage • Current • Timer SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Float Auto / Bypass • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating : 0.5 - 3.0 HP • Phase : Single • Rated Voltage: 220V • Frequency : 50Hz • Voltage Range: 130 - 280V • Max.Current : 20A APPLICATIONS • Tap feeding / domestic water pressure boosting • Overhead tank water distribution • Bathroom & shower pressure boosting • Garden irrigation & lawn sprinklers • Car washing systems SUITABLE FOR PUMPSET • Mini self priming pump • Domestic booster pump • Inline pressure booster pump

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KDP 99 WLC PS Single Phase Submersible Pump Starter Controller with Start, Run Capacitors for Pressure Switch Applications FEATURES STARTER • Electronic starter(Relay Based 40 Amp) DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS •Overload / Over Current(Site Settable) • Dryrun / Under Current(Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current TIMER • Power ON Timer • Dryrun Autostart Timer (Site Settable : Off - 1- 999 min) • Cyclic ON - OFF Timer(Site Settable : Off-1-999 min) • Toggle Timer(Site Settable : Off-1-999 min) TECHNOLOGY • Microcontroller software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS • Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications LED INDICATIONS • Power / Pump ON • OC/ Overload • UC / Dryrun • PS / UTF • LT Empty • Voltage • Current • Timer SWITCHES • ON / Set PC • OFF/ Reset • Auto / Manual • Float Auto / Bypass • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating : 0.5 - 2.0 HP / 3.0HP / 5.0 HP • Phase : Single • Rated Voltage : 220V • Frequency : 50Hz • Voltage Range: 130-280V • Max.Current : 20A / 26A / 40A APPLICATIONS • Ground water supply to water works • Water supply to single / multiple overhead tanks • Domestic and community water supply • Gardening and small farm irrigation SUITABLE FOR PUMPSET • Borewell submersible pumpset • Openwell submersible pumpset • Any pumpset with start & run capacitor requirements

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

AUTOSTARTER WITH 2 INLINE SENSORS Single Phase Municipality Line Automation Controller with Water Level Controller FEATURES STARTER • Electronic starter(Relay Based 30 Amp) TIMER • Power ON Timer TECHNOLOGY • Microcontroller Software Technology Embedded Controller OTHERS • Two tank fully automatic Water Level Controller • Facility to connect Float Switch / Level Sensors / Magnetic Switch etc. LED INDICATIONS • Upper Tank Full • Upper Tank Empty • Pump ON • Lower Tank Full • Lower Tank Empty SWITCHES • WLC Auto / WLC Bypass / Unit OFF TECHNICAL SPECIFICATIONS • Power Rating : 0.5 - 2.0HP • Phase : Single • Rated Voltage : 220V • Frequency : 50Hz • Voltage Range : 130-280V • Max.Current : 15A APPLICATIONS • Booster / municipality line automation SUITABLE FOR PUMPSET • Centrifugal monoblock pumpset

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

svc 22 • Single Phase Solenoid Valve Controller with Water Level Controller FEATURES STARTER • Electronic starter (Relay Based 30 Amp) TIMER • Power ON Timer TECHNOLOGY • Microcontroller Software Technology Embedded Controller OTHERS • Two tank fully automatic •Water Level Controller • Facility to connect Float Switch / Level Sensors / Magnetic Switch etc. LED INDICATIONS • Upper Tank Full • Upper Tank Empty • Pump ON • Lower Tank Full • Lower Tank Empty SWITCHES • WLC Auto / WLC Bypass / Unit OFF TECHNICAL SPECIFICATIONS • Power Rating : 0.5 - 2.0 HP • Phase : Single • Rated Voltage : 220V • Frequency : 50Hz • Voltage Range : 130 - 280V • Max.Current : 15A APPLICATIONS • Automatic water filling for overhead tanks • Borewell / Sumps water flow control • Irrigation system in farms & gardens • Cooling water control in industrial systems SUITABLE FOR • Solenoid valves

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

AUTOSTARTER Single Phase Monoblock Pump Starter with Water Level Controller FEATURES STARTER Electronic starter(Relay Based 30 Amp) TIMER Power ON Timer TECHNOLOGY Microcontroller Software Technology Embedded Controller OTHERS Two tank fully automatic Water Level Controller Facility to connect Float Switch / Level Sensors / Magnetic Switch etc. LED INDICATIONS Upper Tank Full Upp Tank Empty Pump ON Lower Tank Full Lower Tank Empty SWITCHES WLC Auto / WLC Bypas / Unit OFF TECHNICAL SPECIFICATIONS Power Rating : 0.5 - 2.0 HP Phase : Single Rated Voltage : 220V Frequency : 50Hz Voltage Range : 130 - 280V Max.Current : 15A APPLICATIONS Domestic water supply Lawn sprinklers Water supply to overhead tanks Small farm irrigation Dewatering from sumps SUITABLE FOR PUMPSET Monoblock pumpset Self priming pumpset Dewatering pumpset

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

SS 22 WLC Single Phase Monoblock Pump Starter Controller with Water Level Controller FEATURES STARTER • Electronic starter(Relay Based 30 Amp) PROTECTIONS • Overload / Over Current • Dryrun / Under Current TIMER • Power ON Timer TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS • Two tank fully automatic Water Level Controller • Facility to connect Float Switch / Level Sensors / Magnetic Switch etc. LED INDICATIONS • Power / Pump ON • OC / Overload • UC / Dryrun • Upper Tank Full • Lower Tank Empty SWITCHES • Auto / Manual • Pump ON • Pump OFF / Reset TECHNICAL SPECIFICATIONS • Power Rating : 0.5 - 2.0 HP • Phase : Single • Rated Voltage: 220V • Frequency : 50Hz • Voltage Range: 130-280V • Max.Current : 15A APPLICATIONS • Domestic water supply • Lawn sprinklers • Water supply to overhead tanks • Small farm irrigations • Dewatering from sumps SUITABLE FOR PUMPSET • Monoblock pumpset • Self priming pumpset • Dewatering pumpset • Vertical & horizontal multistage pumpset

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

FEATURES STARTER Electronic starter (Relay Based 40 Amp.) DISPLAY Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS Overload / Over Current(Site Settable) Dryrun / Under Current(Site Settable) High / Low Voltage (Site Settable) Extreme High Current TIMER Power ON Timer TECHNOLOGY Microcontroller Software Technology Embedded Controller SETTINGS One touch Pump Current Settings Automatic Protection Settings OTHERS Two tank fully automatic Water Level Controller Facility to connect Float Switch / Level Sensors / Magnetic Switch etc. LED INDICATIONS Power / Pump ON OC / Overload UC / Dryrun UT Full LT Empty Voltage Current Timer SWITCHES ON / Set PC OFF / Reset Auto / Manual Float Auto / Bypass Setting / Accept TECHNICAL SPECIFICATIONS Power Rating : 0.5 - 3.0 HP Phase : Single Rated Voltage: 220V Frequency : 50Hz Voltage Range : 130 - 280V Max.Current APPLICATIONS Domestic water supply Lawn sprinklers Water supply to overhead tanks Small farm irrigation Dewatering from sumps SUITABLE FOR PUMPSET Monoblock pumpset Self priming pumpset Dewatering pumpset Vertical & horizontal multistage pumpset

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KPM 11 TTC Single Phase Openwell Submersible Pump Starter Controller with Start, Run Capacitor and Water Level Controller FEATURES STARTER Electronic starter (Relay Based 40 Amp) DISPLAY Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS Overload / Over Current(Site Settable) Dryrun / Under Current (Site Settable) High / Low Voltage (Site Settable) Extreme High Current TIMER Power ON Timer TECHNOLOGY Microcontroller Software Technology Embedded Controller SETTINGS One touch Pump Current Settings Automatic Protection Settings Password Protection for Settings OTHERS Two tank fullly automatic Water Level Controller Facility to connect Float Switch / Level Sensors / Magnetic Switch etc. SWITCHES Value Setting(4 Switches) ON / OFF Over Current Under Current Auto Manual TECHNICAL SPECIFICATIONS Power Rating : 0.5 - 2.0 HP Phase : Single Rated Voltage: 220V Frequency : 50Hz Voltage Range: 130 - 280V Max. Current : 20A APPLICATIONS Underground tank to overhead tank water transfer Water supply to single / multiple overhead tanks Domestic and community water supply Gardening and small farm irrigation SUITABLE FOR PUMPSET Openwell submersible pumpset Any pumpset with start & run capacitor requirements

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KTC 22 WLC Single Phase Openwell Pump Starter Controller with Run Capacitor and Water Level Controller FEATURES STARTER •Electronic starter (Relay Based 40 Amp.) DISPLAY •Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS •Overload / Over Current (Site Settable ) •Dryrun / Under Current (Site Settable ) •High / Low Voltage(Site Settable ) •Extreme High Current TIMER •Power ON Timer TECHNOLOGY •Microcontroller Software Technology •Embedded Controller SETTINGS •One touch Pump Current Settings •Automatic Protection Settings OTHERS •Two tank fully automatic Water Level Controller •Facility to connect Float Switch / Level Sensors / Magnetic Switch etc. LED INDICATIONS •Power / Pump ON •OC / Overload •UC / Dryrun •UT Full •LT Empty •Voltage •Current •Timer SWITCHES •ON / Set PC •OFF / Reset •Auto / Manual •Float Auto / Bypass •Setting / Accept TECHNICAL SPECIFICATIONS •Power Rating : 0.5 - 3.0 HP •Phase : Single •Rated Voltage : 220V •Frequency : 50Hz •Voltage Range : 130 - 280V •Max.Current : 20A APPLICATIONS •Water supply to single / multiple overhead tanks •Lifting water to apartments, bungalows etc. •Domestic and community water supply •Sprinkler & drip irrigation SUITABLE FOR PUMPSET •Openwell submersible pumpset •Any pumpset with run capacitor requirements

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KPM 11 BORE Single Phase Submersible Pump Starter Controller with Start, Run Capacitors and Water Level Controller FEATURES STARTER Electronic starter (Relay Based 40 Amp.) DISPLAY Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS Overload / Over Current (Site Settable ) Dryrun / Under Current(Site Settable) High / Low Voltage(Site Settable) Extreme High Current TIMER Cyclic ON-OFF Timer(Site Settable: Off - 1 - 999 min ) TECHNOLOGY Microcontroller Software Technology Embedded Controller SETTINGS One touch Pump Current Settings Automatic Protection Settings OTHERS Borewell Automation Controller Facility to connect Float Switch / Level Sensors for Upper Tank SWITCHES Value Setting (4 Switches ) ON / OFF Over Current Under Current OFF Time ON Time TECHNICAL SPECIFICATIONS Power Rating : 0.5 - 2.0 HP Phase : Single Rated Voltage : 220V Frequency : 50Hz Voltage Range : 130 - 280V Max. Current : 20A APPLICATIONS Construction site water supply Water supply for schools, hospitals & institutions Domestic water supply for houses & apartments Gardening and small farm irrigation Agricultural irrigation in farms & fields SUITABLE FOR PUMPSET Borewell submersible pumpset Any pumpset with start & run capacitor requirements

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KDP 99 WLC Single Phase Submersible Pump Starter Controller with Start, Run Capacitors and Water Level Controller FEATURES STARTER Electronic starter (Relay Based 40 Amp.) DISPLAY Sevan Segment Display-Digital Voltmeter & Ammeter PROTECTIONS: Overload / Over Current(Site Settable) Dryrun / Under Current(Site Settable) High / Low Voltage(Site Settable) Extreme High Current TIMER Power ON Timer Dryrun Autostart Timer(Site Settable:Off - 1 - 999 min) Cyclic ON - OFF Timer(Site Settable: Off-1-999 min) TECHNOLOGY Microcontroller Software Technology Embedded Controller SETTINGS One touch Pump Current Settings Automatic Protection Settings OTHERS Two tank fully automatic Water Level Controller Facility to connect Float Switch / Level Sensors / Magnetic Switch etc. LED INDICATIONS Power / Pump ON OC / Overload UC / Dryrun UT Full LT Empty Voltage Current Timer SWITCHES ON / Set PC OFF / Reset Auto / Manual Float Auto / Bypass Setting / Accept TECHNICAL SPECIFICATIONS Power Rating : 0.5 - 2.0 HP /3.0HP / 5.0 HP Phase : Single Rated Voltage : 220V Frequency : 50 Hz Voltage Range : 130 - 280V Max. Current : 20A / 26A/ 40A APPLICATIONS Ground water supply to water works Water supply to single / multiple overhead tanks Domestic and community water supply Gardening and small farm irrigation Dewatering from sumps SUITABLE FOR PUMPSET Borewell submersible pumpset Openwell submersible pumpset Any pumpset with start & run capacitor requirements

6814772a5d263414004dd4a4 Card 2

product image
FULLY AUTOMATIC CONTROLLERS

KDM SD WLC DW Three Phase Star Delta Pump Starter Controller with Water Level Controller for Dewatering Application SEGMENT MODELS Fully Automatic STARTER • Contactor based starter, MCB Included DISPLAY • Seven Segment Display - Digital Voltmeter & Ammeter PROTECTIONS • Phase Failure (Supply Side / Motor Side) • Reverse Phase, Voltage & Current Unbalance • Overload / Over Current (Site Settable) • Dryrun / Under Current (Site Settable) • High / Low Voltage (Site Settable) • Extreme High Current • Moisture Sensor Connection for Leak Detection – Automatically trips the pump upon moisture detection • Thermal Sensor Connection - Provides winding temperature protection by tripping the pump in case of overheating TIMER • Power ON Timer • Star Delta Timer • Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min) TECHNOLOGY • Microcontroller Software Technology Embedded Controller SETTINGS • One touch Pump Current Settings • Automatic Protection Settings OTHERS (FEATURES) • Fully automatic Water Level Controller • Facility to connect Float Switch / Level Sensors / Magnetic Switch etc LED INDICATIONS • Power / Pump ON • SPP / CUB / RP • OC / Overload • UC / Dryrun • Tank Empty • Moisture Sensor • Current • Thermal Sensor SWITCHES • ON / Set PC • OFF / Reset • Auto / Manual • Float Auto / Bypass • Setting / Accept TECHNICAL SPECIFICATIONS • Power Rating: 0.5 - 130 HP • Phase: Three • Rated Voltage: 440V • Frequency: 50Hz • Voltage Range: 280 - 480V APPLICATIONS • Treated water sump drainage • Industrial wastewater handling • Dewatering from sumps • Flood water handling / emergency drainage • Sludge dewatering in STP / ETP SUITABLE FOR PUMPSET • Self-Priming Dewatering Pumps • Centrifugal Dewatering Pumps • High Head Dewatering Pumps • Construction Site Dewatering Pumps • Storm Water / Flood Dewatering Pumps

Phone Number

08043694918

Please keep 0 before dialling the number.

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Address Jai Paruvasu Building level 1&2 , Pisoli , Pune

Pune, India, 411060