WIRELESS M4 GSM MASTER & TANK SET
Three Phase DOL/ Star Delta GSM Master & Tank Controller (Starter Attachment Series)
SEGMENT MODELS
GSM Mobile Starter
STARTER
• Compatible with All Standard DOL and Star-Delta Motor Starters
DISPLAY
• Seven Segment Display - Digital Voltmeter & Ammeter
PROTECTIONS
• Phase Failure (Supply Side / Motor Side)
• Reverse Phase, Voltage & Current Unbalance
• Overload / Over Current (Site Settable)
• Dryrun / Under Current (Site Settable)
• High / Low Voltage (Site Settable)
• Extreme High Current
TIMER
• Power ON Timer
• Dryrun Autostart Timer (Site Settable: Off - 5 - 720 min)
• Cyclic ON - OFF Timer (Site Settable: Off - 5 - 720 min)
• Repeat Run Timer (Site Settable: Off - 5 - 720 min)
• MTC Timer: Clock based 4 ON & 4 OFF Real Time Clock Timers
• Time Compensaon Enable / Disable Facility
TECHNOLOGY
• Microcontroller Software Technology Embedded Controller
SETTINGS
• One touch Pump Current Setting
• Automatic Protection Settings
• Start / Stop / Monitor / Set your Pump from any location
• Device Speaks on Phone Call in Local Language
• Missed Call based ON / OFF Facility
• Call Back Facility for Fault & Power Return
• Get Verbal Voltage & Current information on Phone Call
• Online Parameter Settings by SMS
• Select Auto / Manual Mode on Phone Call
• Add Four Authorized Users
• Site Settable Four Digit Password with SIM Tracking
• SMS Based Android Application & Realme Reports
OTHERS (FEATURES)
• Master Unit: Installed near the pump.
• Tank Unit: Installed near the overhead tank along with a float switch.
• Wireless Communication: The Master Unit and Tank Unit communicate with each other via SIM card (GSM network).
• Automatic Operation: Ensures the tank remains filled at all times by automatically controlling the pump based on the float switch level.
LED INDICATIONS
Master Unit
• Healthy / Pump ON
• SPP / CUB / RP
• OC / Overload
• UC / Dryrun
• Timer
• Voltage
• Current
• SMS / Ring
• Network
Tank Unit
• Power
• Voltage
• WLC Byp
• Low Battery
• Feedback Error
• Upper Tank Full
• SMS / Ring
• Upper Tank Empty
• Network
SWITCHES
Master Unit
• ON / Set PC
• OFF / Reset
• Auto / Manual
• Unit ON / Unit OFF
• Setting / Accept
Tank Unit
• ON
• OFF / Reset
• Unit ON / Unit OFF
• Battery ON / Battery OFF
• Setting / Accept
TECHNICAL SPECIFICATIONS
• Power Rating: 0.5 - 60 HP
• Phase: Three
• Rated Voltage: 440V
• Frequency: 50Hz
• Voltage Range: 280 - 480V
• Max. Current: 99A
APPLICATIONS
• Construction site
• Domestic and community water supply
• Water supplies for high rise building
• Irrigation in Horticulture & Agriculture
• Small farm Irrigation
• Industrial Machines, Fans & Blowers
• Dewatering from sumps
SUITABLE FOR PUMPSET
• All types of DOL / Star Delta Pumpset
• Borewell & Openwell Subersible Pumpset
• Centrifugal Monoblock Pumpset
• Dewatering DOL Pumpset
• Induction Motors
• Conveyors, Mixers & Agitators
KHP SD DW
•Three Phase Star Delta Multi Pump Fixed Speed Automation Controller
FEATURES
STARTER
•Contactor based starter , MCB Included
DISPLAY
•Seven Segment Display - Digital Voltmeter & Ammeter
PROTECTIONS
•Phase Failure(Supply Side)
•Reverse Phase, Voltage Unbalance
•Overload / Over Current (Site Settable )
•Dryrun / Under Current (Site Settable)
TIMERS
•Power ON Timer
•Dryrun Autostart Timer(Site Settable : Off-1-999 min)
•Toggle Timer (Site Settable : Off - 1 - 999 min )
•Cyclic ON - OFF / Force Changeover Timer(Site Settable : Off - 1 - 999 min)
TECHNOLOGY
•Microcontroller Software Technology Embedded Controller
SETTINGS
•All Parameters Fully Configurable at Site
OTHERS
•Facility to connect Pressure •Switch / Float Switch for •Automatic Water Level •Control for Tap Feeding / •Tank Filling applicatioons
LED INDICATIONS
•Healthy
•SPP / VUB / RP
•OC / Overload
•UC / Dryrun
•LT Empty
•Pump 1
•UT Full
•Pump 2
SWITCHES
•ON / Set PC
•OFF / Reset
•Auto / Manual
•Pump 1 / Pump 2 / •Alternate
•Setting / Accept
TECHNICAL SPECIFICATIONS
•Power Rating : 0.5 - 60 HP
•Phase : Three
•Rated Voltage : 440V
•Frequency : 50Hz
•Voltage Range : 280 - 500V
APPLICATIONS
•Booster pumps in high rise buildings
•Hydro pneumatic water supply systems
•Industrial pressure boosting pumps
•Fire line main pump systems
•Process water pressure system in industries
SUITABLE FOR PUMPSET
•Submersible / Openwell star delta pumpset
•End suction centrifugal star delta pumpset
•Vertical multistage star delta pumpset
•Horizontal split case star delta pumpset
•Fire fighting main pump star delta pumpset
KHP STP
Three Phase DOL Multi Pump Fixed Speed Automation Controller
FEATURES
STARTER
• Premium / Classic - •Contactor based starter, •MCB Included Lite - •Electronic starter (Relay Based 40 Amp )
DISPLAY
•Seven Segment Display - Digital Voltmeter & Ammeter
PROTECTIONS
•Phase Failure (Supply Side)
•Reverse Phase, Voltage Unbalance
•Overload / Over Current (Site Settable)
•Dryrun / Under Current (Site Settable)
TIMERS
•Power ON Timer
•Dryrun Autostart Timer (Site Settable : Off - 1 - 999 min)
•Toggle Timer (Site Settable : Off - 1 - 999 min )
•Cyclic ON - OFF / Force Changeover Timer (Site Settable : Off - 1 - 999 min)
TECHNOLOGY
• Microcontroller Software Technology Embedded Controller
SETTINGS
• All Parameters Fully Configurable at Site
OTHERS
•Facility to connect Pressure Switch / Float Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applicatiions
LED INDICATIONS
• Healthy
• SPP / VUB / RP
• OC / Overload
• UC / Dryrun
• LT Empty
• Pump 1
• UT Full
• Pump 2
SWITCHES
• ON / Set PC
• OFF / Reset
• Auto / Manual
• Pump 1 / Pump 2 / Alternate
• Setting / Accept
TECHNICAL SPECIFICATIONS
• Power Rating : 0.5 - 5.0 HP / 7.5 HP
• Phase : Three
• Rated Voltage : 440V
• Frequency : 50Hz
• Voltage Range : 280 - 500V
• Max.Current : 16A
APPLICATIONS
• Water transfer booster systems
• AHU in HVAC systems
• Industrial water pressure control
• Fire line jockey pump systems
SUITABLE FOR PUMPSET
• Centrifugal monoblock pumpset
• End suction pumpset
• Multistage booster pumpset
Air handling (AHU)
KHP DOL DW
Three Phase DOL Multi Pump Fixed Speed Automation Controller
FEATURES
STARTER
• Premium / Classic - Contactor based starter, •MCB Included Lite - Electronic starter (Relay Based 40 Amp)
DISPLAY
• Seven Segment Display - Digital Voltmeter & Ammeter
PROTECTIONS
• Phase Failure (Supply Side)
• Reverse Phase, Voltage Unbalance
• Overload / Over Current (Site Settable)
• Dryrun / Under Current(Site Settable)
TIMERS
• Power ON Timer
• Dryrun Autostart •Timer(Site Settable : Off-1-999 min)
• Toggle Timer (Site Settable : Off - 1-999 min)
• Cyclic ON - OFF / Force Changeover Timer (Site Settable : Off - 1 - 999 min )
TECHNOLOGY
• Microcontroller Software Technology Embedded Controller
SETTINGS
• All Parameter Fully Configurable at Site
OTHERS
• Facility to connect Pressure Switch / Float •Switch for Automatic Water Level Control for Tap Feeding / Tank Filling applications
LED INDICATIONS
• Healthy
•SPP / VUB / RP
• OC / Overload
• UC / Dryrun
• LT Empty
• Pump 1
• UT Full
• Pump 2
SWITCHES
• ON / Set PC
• OFF / Reset
• Auto / Manual
• Pump 1 / Pump 2 / Alternate
• Setting / Accept
TECHNICAL SPECIFICATIONS
• Power Rating : 0.5 - 5.0 HP / 7.5 HP
• Phase : Three
• Rated Voltage 440V
• Frequency : 50Hz
• Voltage Range : 280 - 500V
• Max.Current : 16A
APPLICATIONS
• Water transfere booster systems
• AHU in HVAC systems
• Industrial water pressure control
• Fire line jockey pump systems
SUITABLE FOR PUMPSET
• Centrifugal monoblock pumpset
• End suction pumpset
• Multistage booster pumpset
Air handling Unit (AHU)